11. Turn control power

ON

. The

PV

LED displays four zeros (

0000

), then displays the

current process air temperature.

Caution!

Do not attempt to run the controller without an output load.

The contactors could be damaged!

12. Press

to page through Level

0

control parameters. The

PV

LED displays codes

indicating the currently selected mode; the

SV

LED shows the current setting of the

selected parameter. Use

and

to select a setting.

13. Set Level 0 parameters based on Figure 12 on the following page.

14. Press

for at least two seconds to access Level

1

parameters. Set them using the

procedure in the previous step.

Note: You can proceed to Level

2

, but these parameters are read-only. Controllers with optional

communications have user-set variables (unit address and ID) on Level

2

.

15. Turn off the power switch on the graphic display and remove all electrical power to the

dryer.