Level 2 controllers – AEC WD 350 through WD3000 Dehumidifying Dryers User Manual
Page 47
1. Press up the latch at the bottom of the control module front panel
and slide out the control chassis.
Celsius Setup
1
2
3
4
5
6
ON
OFF
2. Locate the six-position DIP switch on the circuit board.
3. Move Switch
6
to the
OFF
position for Celsius.
4. Slide the chassis back into the control module housing.
5. Cover the
°F
label with the
°C
label included in the information packet.
6. Reinstall the control and start the dryer unit.
Level 2 Controllers
1. Shut off power to the dryer and remove the controller from the chassis.
2. After setting all internal switch settings, set switch
4
of the function switch to
ON
. This
switch is normally set to
OFF
.
3. Insert the internal mechanism into the housing and power up the temperature controller.
(du) displays.
4. Press
to select the set value display as Celsius (ºC) or Fahrenheit (ºF).
5. Turn off the power two (2) seconds after the set value display changes.
6. Remove the internal mechanism from the housing, set pin number
4
of the function
switch to
OFF
, replace it and turn on the power.
Page 46