Level 1 controllers, Caution – AEC WD 350 through WD3000 Dehumidifying Dryers User Manual

Page 56

background image

6. Re-install the new heaters in reverse order. Install new heater gaskets (AEC Part No.

W00018316) and securely tighten all fasteners.

Caution!

Heater loops should not touch each other.

“Hot spots” lead to premature heater failure!

7. Re-install the wiring based on the sketch you made earlier.

8. Secure the heater access cover.

7-8 Restoring the Temperature Controller to Factory

Setup

Level 1 Controllers

If preset parameters on the controller have been tampered with and it no longer properly controls
temperature, you can restore it to the factory setup. Perform the following procedures to restore
factory setup:

1. Turn off the power switch on the graphic display and remove all electrical power to the

dryer.

1. Press up the latch at the bottom of the module front panel and slide out the control

chassis.

PROTECT OFF

OFF

ON

1. Locate the slide-type lockout switch marked

PROTECT OFF

on the

circuit board. It should be

OFF

.

0

1

2

3

4

5

6

7

8

9

ALARM

2. Set the rotary-type alarm mode selector switch marked

ALARM

to Position

2

for the upper limit alarm with standby.

3. Set the rotary temperature sensor selector switch located to the left of the

ALARM

selector switch to Position

2

. Your dryer is factory-equipped with Type K thermocouples;

you can use six (6) other temperature sensor types if you properly set the switch.

WDMR and WDFR Series Dehumidifying Dryers