Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual
Page 32
CliCk 111 • User GUIde
31
Note
This parameter can only be configured using Click Supervisor.
Setting
Description
Module
Allows you to enter a name and description of the device.
Driver
Names the driver you are currently working with. This parameter can-
not be edited.
Description
Shows a description of the device being configured. This is only for
your information and does not affect the operation of the device.
Location
Displays the location of the device being configured. This is only for
your information and does not affect the operation of the device.
Serial Number
Displays the serial number of your device. This information cannot be
changed.
Firmware Version
Shows the version of firmware your device currently has installed. If
Click Supervisor detects a discrepancy between this version and the
most current version it currently has access to, you will be prompted
to upgrade when you connect to the device. This information cannot
be changed.
Subnet ID
Shows the subnet ID number. This option is currently not available.
Device ID
Gives the ID number of the device being configured, which is used
to identify the device when you are connecting to it. By default, this
number is the last five digits of the serial number, which can be found
under the About tab or on the barcode sticker on the bottom of the
device. It is recommended that you do not change this number unless
another device on your network has the same ID number.
Table 19 – Expert Driver General Tab
The System > Settings tabs lets you configure and view many of the parameters that are also
available elsewhere on the device (see Table 2 earlier in this chapter for more information).
There are two settings tabs, Settings 1 and Settings 2. The Settings 1 tab has the following
parameters (see Figure 10 and Table 20):