Baud rate (bus 1 and 2), Base channel – Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual
Page 24
CliCk 111 • User GUIde
23
Baud Rate (Bus 1 and 2)
The next parameters we’ll talk about allow you to manually set the baud rate of the two RS-
485 buses. Bus 1 comes up first, with the green and yellow LEDs coming on together; bus 2
comes up second, with the blue LED glowing solid.
Note
This parameter can also be changed using the DIP switches or Click Supervisor.
Level 1 LEDs
Baud rate for bus 1
Baud rate for bus 2
Level 2 LEDs
9600 bps (default)
19200 bps
38400 bps
57600 bps
LED off
LED on
Cancel and exit menu
Table 11 – Front Panel Menu Baud Rate Settings
See the earlier Navigating through the Menu and the Menu Operation Example sections for
how to configure this parameter.
Because this parameter can also be set by the DIP switches, you may need to ensure that the
DIP switches are set to Software configuration mode; if they are set to Hardware, the front
panel menu will be able to display but not change these settings.
Base Channel
The next parameter on the front panel menu label is the base channel. This can be set in-
dependently for the two buses. To select this parameter for bus 1, release the push-button
when the yellow and blue LEDs both come on solid; for bus 2, release the push-button when
the green and blue LEDs both come on solid.
Note
This parameter can also be changed using the DIP switches or Click Supervisor.