beautypg.com

Bus data enable – Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual

Page 21

background image

20

CliCk 111 User GUIde

Figure 7 – Front Panel Menu Label

As shown above, the menu options are displayed on the Level 1 LEDs and the configuration

parameters are displayed on the Level 2 LEDs.

If a configuration parameter has been set using the DIP switches (meaning that parameter

is currently set to Hardware mode), you cannot change it using the front panel menu. After

selecting that particular menu option from the Level 1 LEDs, the Level 2 LEDs will display

the configuration option set in the DIP switches and will not allow you to switch from that

option. The only way to exit at this point is to press the push-button once.

Note

Certain older Click 111 devices may have slightly different labels; be aware that any-
where the label differs from the text in this chapter, the chapter is correct.

Bus Data Enable

The first parameter on the menu label is bus data enable. To select this parameter, release