beautypg.com

Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual

Page 22

background image

CliCk 111 • User GUIde

21

the push-button when the yellow LED in the comes on.

Note

This parameter can also be changed using the DIP switches or Click Supervisor.

This group of DIP switches determines whether the data buses are enabled to receive con-

tact closure data. Each bus can be independently enabled or disabled.

This parameter may be useful if you know a bus will not be receiving any data—for instance, if

you’re only using one sensor with your Click 111. If a bus is disabled from receiving data, then

its associated channels will not go into a fault state, even if that bus is not receiving any data.

Note

If you’ve disabled a bus from receiving data, you can still use it to configure the card
using Click Supervisor.

A disabled output will never enter the detection state, and will never indicate a fault condi-

tion. Any combination of outputs can be enabled. Due to limited space on the side label, not

all combinations of enabled and disabled channels are listed. A complete table is shown below.

Level 1 LEDs

Bus Data Enable

Level 2 LEDs

Bus 1 & 2 Data Disabled

Bus 1 Data Enabled, Bus 2
Data Disabled

Bus 1 Data Disabled, Bus 2
Data Enabled

Bus 1 & 2 Data Enabled
(Default)

LED off
LED on

Cancel and exit menu

Table 9 – Front Panel Menu Bus Data Enable Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.

Because this parameter can also be set by the DIP switches, you may need to ensure that the

DIP switches are set to Software configuration mode; if they are set to Hardware, the front

panel menu will be able to display but not change these settings.