beautypg.com

Example – Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual

Page 25

background image

24

CliCk 111 User GUIde

This parameter selects how the Click 111 maps the incoming sensor outputs to the card’s

outputs. The setting determines the starting sensor channel that will be mapped to the as-

sociated bus channel 1 output.

Example

If you have this parameter set to 3 for bus 1, then sensor channel 3 will be mapped
to output channel 1 on bus 1. And then the card will count up from there: if the bus
has four channels allocated to it, then sensor channel 4 will be mapped to output 2,
sensor channel 5 will be mapped to output 3, and sensor channel 6 will be mapped
to output 4.

Level 1 LEDs

Base channel for bus 1

Base channel for bus 2

Level 2 LEDs

Channel 1

Channel 3

Channel 5

Channel 7

Channel 9

Channel 11

Channel 13

Channel 15

Channel 17

Channel 19

Channel 21

Channel 23

Channel 25

Channel 27

LED off
LED on

Cancel and exit menu

Table 12 – Front Panel Menu Base Channel Settings

See the earlier Navigating through the Menu and the Menu Operation Example sections for

how to configure this parameter.