Example – Wavetronix Click 111 (16-channel Contact Closure Eurocard) (CLK-111) - User Guide User Manual
Page 14
CliCk 111 • User GUIde
13
Example
If you have this parameter set to 5 for bus 2, then sensor channel 5 will be mapped
to output channel 1 on bus 2. And then the card will count up from there: if the bus
has four channels allocated to it, then sensor channel 6 will be mapped to output 2,
sensor channel 7 will be mapped to output 3, and sensor channel 8 will be mapped
to output 4.
Note
This parameter can also be changed using the front panel menu or Click Supervisor.
The switch patterns for the two parameters are identical, but bus 1 is configured using
switches 1–4 (S2:1–4) while bus 2 is configured using switches 5–8 (S2:5–8).
S2: Bus 1 Base Channel
1
2
3
4
Base Channel
Off
Off
Off
Off
Software mode
Off
Off
Off
On
1
Off
Off
On
Off
3
Off
Off
On
On
5
Off
On
Off
Off
7
Off
On
Off
On
9
Off
On
On
Off
11
Off
On
On
On
13
On
Off
Off
Off
15
On
Off
Off
On
17
On
Off
On
Off
19
On
Off
On
On
21
On
On
Off
Off
23
On
On
Off
On
25
On
On
On
Off
27
On
On
On
On
29
S2: Bus 2 Base Channel
5
6
7
8
Base Channel
Off
Off
Off
Off
Software mode
Off
Off
Off
On
1
Off
Off
On
Off
3
Off
Off
On
On
5
Off
On
Off
Off
7
Off
On
Off
On
9
Off
On
On
Off
11
Off
On
On
On
13
On
Off
Off
Off
15
On
Off
Off
On
17
On
Off
On
Off
19
On
Off
On
On
21
On
On
Off
Off
23
On
On
Off
On
25
On
On
On
Off
27
On
On
On
On
29
Table 4 – DIP Switch Base Channel Settings for Bus 1 (left) and Bus 2 (right)
If any of the switches are on (flipped up), Hardware mode is selected, meaning the base
channel will be configured using the DIP switches, and Click Supervisor and the front panel