CliCk 111 • User GUIde

9

Preparing the SmartSensor

In addition to wiring the SmartSensor to the Click 111, you must also make sure that the

SmartSensor is configured correctly. Because the Click 111 device receives serial datagrams

from the sensor, the sensor must be configured to report data properly for each application.

This may include loop emulation settings and/or output channel configuration.

Fault State

The Click 111 receives datagrams from the connected SmartSensor, and it’s looking for

datagrams containing detection data that’s intended for one of its output channels. If a bus

does not receive such a datagram for ten seconds, it will go into a fault state. (The fault time-

out can be changed using Click Supervisor software, as will be discussed later in this guide.)

Each data bus can go into a fault state independently. The state of the output channels, when

they are in fault, can be configured as either a call or a no call.

If either of the buses go into a fault state then the master fault will be asserted. The card has

one master fault indicator (the blue LED on the faceplate of the device) and an associated

output on the back connector. You can disable failsafe for the whole card if you desire.

Configuration

The Click 111 can be configured in three ways: DIP switches, the front panel menu, and

Click Supervisor.

These three different configuration methods can configure different sets of options; some of

these parameters can be set using multiple configuration methods, and some of them can

only be set using one particular method. Table 2 lists how each parameter may be accessed

and configured.

DIP Switch

Front Panel Menu Click Supervisor

Baud Rate

Yes

Yes

Yes

Base Channel

Yes

Yes

Yes

Channel Allocation

Yes

Yes

Yes

Data Enable

Yes

Yes

Yes

Channel Output Polarity

Yes

Yes

Yes

Fault Output Polarity

Yes

Yes

Yes

Fault Enable

Yes

Yes

Yes

Fault State

Yes

Yes

Yes

Autobaud

No

Yes

No

Reset to Defaults

No

Yes

Yes

Description

No

No

Yes