WallWizard X700CB Manual User Manual
Page 26

2
www.closystems.com
“H1”, “H2”, or “H3” is displayed on control box
Possible Causes:
A cable has become disconnected.
A “stop” switch is faulty.
There is dirty or debris in one of the switches.
How to Correct:
1. Unplug X-arm
™
from power.
2. Check that the TV and X-arm
™
are not trapped against the wall or any other object.
3. Plug in X-arm
™,
turn on the power and try to move the X-arm
™
using the remote control.
If it works properly, do not continue to step 4.
4. Turn the power switch on the control box to “0” (OFF).
5. With the X-arm
™
powered on, insert the provided plastic
pointer in the Selector hole on the side of the X-arm
™
and
press it until “t” shows on the LED display.
6. Using the remote control, straighten X-arm
™
so that it is
parallel with the wall, and then press the “Set” button on the
control box for three seconds. The X-arm
™
should return to
the home position against the wall.
7. Unplug X-arm
™
from power for at least 10 seconds and then
plug it in again. Turn on the power and try to move the X-
arm
™
using the remote control. Continue to step 8 if it does
not work correctly.
8. Unplug the X-arm
™
from power.
9. Remove the TV and inspect the areas in the
picture corresponding to the error message.
For example, if H3 is displayed on the LED,
look at areas in the H3 circle. Make sure that
all motor and “stop” switch wire connections
are securely connected.
10. Clean any substances or particles from the
long drive screws.
11. Plug in X-arm™, turn on the power and try to
move the X-arm
™
using the remote control.
•
•
•
H1
H2
H3
Set
Power Switch
Control Box
LED Display
Selector
Set Button