11. Prepare the proper length Ethernet cables to attach the Thin
Client / workstation(s) to your network.
12. Assure power is available for each Thin Client / workstation (i.e.
there must be a power strip within reach of the workstation).
13. Check connectivity between all the proposed IP addresses
assigned for MCC use (pinging in both directions is satisfactory).
14. Prepare the proper length coax cables to attach the console(s) and
printer console(s). DO NOT USE BALUNS.
15. Prepare the proper length and type of cables to attach the “System
console(s)” - please check that you have the proper cable
Sites with MVS systems:
1. Provide the ipaddress(es) for SCON units.
2. Provide the TCP/IP port to be used for MCC server and
MCCSTARS software. The default is port 2769
3. Assign one non-SNA (327x) alternate console address for each
LPAR the MCC will monitor.
4. Update the MVS/VM software (e.g. MVS CONSOLxx member) as
required.
5. Check connectivity between the control unit(s) and the assigned
addresses using a standard 327x terminal or TN3270 client to
ensure they are properly defined.
6. Supply a printout of the addresses to Visara in input format (e.g.,
for each MVS LPAR, supply the CONSOLxx member that will be
used to IPL in an MCC environment)
7. Supply a printout of the addresses to Visara in output format (e.g.,
for each MVS LPAR, supply the output of a “D C” command when
the proposed console is active (in use).
8. Assign one alternate “System Console” (for IPL/NIP) for each
physical machine on which LPAR monitoring will occur.
9. Update the MVS/VM software (e.g. MVSCP or HCD member) as
required (e.g., MVS NIPCON addresses) to add in the “new
System Console(s)” from which an IPL can be performed; for
testing, the “new” System Console should always be the
“alternate” (not the primary) console from which an IPL can be
performed