beautypg.com

Alarms/statistics menu (t1/ft1 mode), Alarms/statistics menu (t1/ft1 mode) -6, Front panel operation -29 – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual

Page 72

background image

Other Features

5-6

AS56 and AS56

Plus

User Manual

Alarms/Statistics Menu (T1/FT1 Mode)

Please refer to Alarm and ESF Statistics Definitions previously described
in this chapter.

This chapter describes front panel access of the Alarms and Statistics
storage. Please refer to Chapter 6, Auxiliary Ports for terminal access.

From the Alarms/Stats Main Menu,

SELECT

then use

UP/DOWN

arrows

to display either NI Alarms or ESF Statistics. Then

SELECT

followed

by

UP/DOWN

as described below.

NI Alarms will display the current status (Yes/No) of AIS, Red and
Yellow Alarms, Frame Errors (Ferr), CRC6, LOS, and BPV alarms.

UP/

DOWN

will scroll through the seven possible alarms. If any entry is yes,

the display will also indicate the quantity of seconds that the alarm has
been present.

If ESF Statistics is selected, the user is then presented with another
choice, Current Statistics, 24-Hour Statistics, or ESF Registers.

By choosing Current Statistics, the user is provided statistics for the
current time interval (maximum fifteen minutes). Use

UP/DOWN

to scroll

through the following:

Current Status

ES & FS

SES & BES

LOFC

Time in Current Interval (in seconds)

the current quantity of Valid Intervals (fifteen minutes per interval).

In the Current Status screen (shown below), the following interpretation
applies.

Current Stats

Status: XX0000X0