beautypg.com

Line loop, Line loop -6 – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual

Page 60

background image

Testing the Access System 56

4-6

AS56 and AS56

Plus

User Manual

Line Loop

LLB causes a local line loop (at the Acce ss System56 unit where the
command was entered). RLB causes a remote line loop (at the distant end
of a point-to-point circuit); RLB should not be attempted in an Integrated
Access, Fractional T1 environment.

The CSU is excluded from the test path in a Line Loop configuration.

In a point-to-point circuit, the LLB and RLB are useful for looping back
any testing initiated by the other end, such as Payload BERT, Serial Port
BERT, or any externally generated testing.

In an Integrated Access, Fractional T1 circuit, LLB is useful for looping
back Serial Port testing initiated by any remote location.

WHEN TESTING IS COMPLETED, BE SURE TO TURN THE LOOP
“OFF”.

SELECT

as required to turn the loop Off/On.

Diagnostics

_Ntwk Port

From Diag. Menu,

UP/DOWN

to

display:

NI Diagnostics

NI LLB...:_On

SELEC

, then

DOWN

as required

to display:

NI Diagnostics

NI RLB...:_On

OR

1.536 Mbps

1.544 Mbps

Line Loop ON

Payload

Networ

Interface

To

DTE