Configuring and Installing the Access Syste m56
3-26
AS56 and AS56
Plus
User Manual
If the remote end responds properly to this command, the Network
LOOP
indicator will illuminate within approximately ten seconds. If the remote
end does not respond properly, the
LOOP
indicator will remain
extinguished and the LCD panel will change to NI RLB..:_Off.
Confirm that the remote end has responded properly. If it has not, check
the Network cable connections and try again. If it still does not respond,
contact your network supplier. Continue with the following steps only if
the remote end has responded properly.
Confirm that the Seconds/Test is properly incrementing and then depress
UP
to confirm that the Errored Seconds is not incrementing. If the unit is
receiving errored seconds, confirm your configuration and run the testing
again. If the unit still indicates errored seconds, contact our Technical
Assistance Center.
NI Diagnostics
NI RLB..:_Off
DOWN
as required
to display:
NI Diagnostics
NI RLB..:_On
SELECT
to display:
NI Diagnostics
BERT......:_On
DOWN
as required and
SELECT
to display:
NI Diagnostics
Err Secs.:_00000
DOWN
as required and
SELECT
to display:
NI Diagnostics
Sec/Test.:_00000
DOWN
as required and
SELECT
to display: