Verilink AS56/56Plus (896-502588-001) Product Manual User Manual
Page 18

Overview
1-6
AS56 and AS56
Plus
User Manual
N
ETWORK
I
NTERFACE
56/64 kbps DDS Mode
Interface
Integral 56/64 kbps DDS CSU
Format
Full 56/64 kbps DDS Compatibility per AT&T Tech Pubs 62310
(Subrate speeds: 2400, 4800, 9600, 19200, 56000, and 64000)
Line Rate
56/64 kbps Bipolar AMI, RTZ
Interface
Female, 8-position RJ-48C
T1/FT1 Mode
Interface
Integral ESF CSU
Framing
Full ESF/D4 Compatibility per AT&T Tech Pubs 62411, 54019, and ANSI T1.403
Line Rate
1.544 Mbps +/- 50 ppm, Bipolar AMI or B8ZS
LBO
0, 7.5, 15, 22.5 dB
Termination
Female, 8-position RJ-48C
T
IMING
Clock Sources
Internal
Frequency locked to Network (looptime)
Frequency locked to Synchronous Serial Port
N
ETWORK
D
IAGNOSTICS
Local Loops
CSU, Line (LLB) and Payload loops
Remote Loops
Line (LLB), Payload and V.54 Compliant loops
Test Patterns
2047 (DDS and T1 Modes)
1 of 8, 3 of 24, All Ones (T1 Mode Only)
S
ERIAL
D
ATA
I
NTERFACE
# of Ports
1 standard
Input Data Rates
56/64 kbps
N x 56/64 Kbps for N= 1 to 24, up to 1.536 Mbps
Interfaces
Female 25-pin “D”.
Software selectable V.35, RS-530, RS-232
LED I
NDICATORS
Network
Loop, Density, BPV, Alarm
Serial Port
Test, Loop, DC
P
ROGRAMMING
Front Panel
32 Character Liquid Crystal Display with front panel buttons
SNMP Manager with integrated agent software
ASCII Terminal
Alarm Printer
M
ECHANICAL
Dimensions
8.35” W X 1.75” H X 10” D
Weight
7 pounds (maximum)
Mounting
Tabletop or Rack
Power
Integral supply, 90-230 Vac, 47-63 Hz
Environment
0 to 40 degrees C, 90% humidity (non-condensing)