Other features, Alarms and statistics, T1/ft1 mode – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual
Page 67: Other features 5-1, Alarms and statistics -1, T1/ft1 mode -1, Chapter

AS56 and AS56
Plus
User Manual
5-1
Chapter
5
Other Features
Many other functions are available in the Access Sy stem56. This chapter
describes access from the front panel display. The same functions can
also be accessed via an externally attached terminal. See Chapter 6,
Auxiliary Ports .
Alarms and Statistics
This section discusses the alarms and statistics available in T1/FT1 mode
and 56/64 kbps DDS mode.
T1/FT1 mode
The Alarms and Stats Main Menu is intended for those users with T1
alarm and ESF (Extended Superframe) statistics knowledge. From the
Alarms and Stats Main Menu,
SELECT
then use
UP/DOWN
arrows to:
■
Access current network alarm conditions, which are shown with the
number of seconds that the alarms have been present since the last
alarm reset.
■
Reset the alarm times.
■
Access both current and 24-hour ESF statistics.
■
Access the current ESF registers.
■
Send alarms to an externally attached printer. See Chapter 6,
Auxiliary Ports.
■
Send ESF statistics to an externally attached printer. See Chapter 6,
Auxiliary Ports.