Location

Air cooled models take room temperature air in

from the left side and discharge warm air out the

back. Do not place them where the heat and noise

will be objectionable.
A 6 inch MINIMUM clearance between the back

and a wall and between the left side and a wall or

another product is required for the basic operation

and service of the air cooled model.

Note: A six inch side clearance with zero top

clearance will NOT provide enough air exchange

space for optimum performance. 12 inches side

clearance is required when there is no top

clearance.

Air cooled models come equipped with a baffle

that can be used when the machine is installed

in a corner.
The purpose of the baffle is to limit air

recirculation. This can occur in a corner when the

hot air from the back of the machine is re-drawn

back into the machine from the nearest side of the

machine.
Install the air baffle as shown on the left rear

corner when a side wall and back wall are between

6 and 18 inches from the unit.

CME306 & CME456

January 2000

Page 6

Air

Baffle

Back View of Ice

Machine

Remove Air Baffle from its

Shipping Position.

Baffle Position

Baffle

Ice Machine

Top View

Ice Machine

Top View

Wall

Wall

Use baffle for

In-The-Corner Applications

Condenser

Outlet

Attach

Baffle

Here

Airflow is

in the left

side and

out the

back

This manual is related to the following products: