Specifications
This ice machine is designed to be installed
indoors, in a controlled environment. It will operate
satisfactorily under a wide variety of conditions. Do
NOT operate the machine in temperatures it has
not been designed for. Do NOT operate the
machine above or below the voltage limits for the
particular model. Do NOT operate the machine
with too little or too much water pressure.
Operational Limits
Minimum Maximum
Air Temperature
50
o
F.
100
o
F.
Water Temperature
40
o
F.
100
o
F.
Water Pressure
20 psi
80 psi
Voltage (115 volt models)
104
126
Voltage (208-230 v models)
198
253
Voltage (50 Hz models)
207
253
Inlet water flow required is 1.25 GPM.
All models will fit a standard, 22" wide Scotsman
Ice Storage Bin such as the BH360.
Note: Slope front bins may need an internal baffle.
Scotsman’s BH360 has the required baffle. Baffle
must be approximately in the position shown in the
diagram on page 5.
Note: The ice machine will hang over the back of
the Lancer dispensers shown in the following list.
In addition, there may be other bins that can be
used, check Scotsman’s sales literature for
application information.
Note: This unit may not be stacked.
Bin and Dispenser Applications & Kits:
•
BH360 bin: Direct Fit
•
HD22 dispenser: Direct Fit.
•
ID150, add adapter kit KBT42
•
ID200 or 250, add adapter kit KBT43
•
Lancer 22” wide model: Add kit A37693-021.
•
Lancer 30” wide model: Add kit KLD22-30.
•
HTB555 - Add bin top kit KBT27
•
Bin’s with short/no baffle require thermostat
kit: KSTAT-22.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
CME306 & CME456
May 2004
Page 2
Model Number
Series
Dimensions
W" x D" x H"
(w/o bin)
Basic
Electrical
Condenser
Type
Minimum
Circuit
Ampacity
Max
Fuse*
Size
Refrigerant
Charge
(R-404A)
CME306AS-1
A, B or C
22 x 24 x 28
115/60/1
Air Cooled
16
20
23 ounces
CME306AS-32
A, B or C
same
208-230/60/1
Air Cooled
7.9
15
23 ounces
CME306AS-6
A, B or C
same
230/50/1
Air Cooled
15
15
23 ounces
CME306WS-1
A
same
115/60/1
Water Cooled
16
20
15 ounces
CME306WS-32
B or C
same
208-230/60/1
Water Cooled
7.4
15
13 ounces
CME306WS-6
A
same
230/50/1
Water Cooled
15
15
15 ounces
CME306WS-1
B or C
same
115-60/1
Water Cooled
16
20
13 ounces
CME306WS-1
B or C
same
230/50/1
Water Cooled
15
15
13 ounces
CME456AS-1
A, B or C
same
115/60/1
Air Cooled
19
20
24 ounces
CME456AS-32
A, B or C
same
208-230/60/1
Air Cooled
9.8
15
24 ounces
CME456WS-1
A
same
115/60/1
Water Cooled
19
20
17 ounces
CME456WS-1
B or C
same
115/60/1
Water Cooled
19
20
14 ounces
CME456WS-32
B or C
same
208-230/60/1
Water Cooled
9.2
15
14 ounces
CME456AS-6
A, B or C
same
230/50/1
Air Cooled
7.9
15
24 ounces
CME456WS-6
A
same
230/50/1
Water Cooled
7.1
15
17 ounces
CME456WS-6
B or C
same
230/50/1
Water Cooled
7.1
15
14 ounces
* Or HACR circuit breakers.
Basic Information