Adjustments

If there was a problem during Initial Start

Up:

If an error light came on, check the following.
1. Water error.
A water error could have been determined by the

AutoIQ Controller if the inlet water valve does not

fill the reservoir, or if the water pump does not start

and lower the water level.
2. Refrigeration error.
A refrigeration error could have been determined

by the AutoIQ Controller if the water temperature

did not drop during the freeze cycle. The controller

will next check the compressor discharge

temperature, If the discharge temperature is too

low, the refrigerant error light will be switched on,

and the machine will Shut Down.
Note: Reset and restart the machine by

pushing and releasing the Off push button

switch, and then pushing and releasing the

freeze push button switch.

Adjustments

How to adjust the water cooled discharge pressure
Water cooled models use a water regulating valve

to control how much cooling water flows thru the

water cooled condenser. At the top of that valve,

located in the back of the ice machine, is an

adjustment stem.
To Adjust:
1. Attach a refrigeration manifold gage to the

discharge access valve.
2. While the unit is in the freeze cycle, determine

the discharge pressure, it should be about 245

PSIG.
3. If needed, rotate the adjustment stem to

increase or decrease the pressure:
A. To increase discharge pressure (reduce water

flow) rotate the stem counter-clockwise.
B. To decrease the discharge pressure (increase

water flow) rotate the stem clockwise.
Remove the manifold when done. Note: The water

outlet temperature should be between 100-110

when the valve is properly set.

Thermostatic Expansion Valve:

The TXV is not adjustable, do not attempt to adjust

it.

How to Adjust the Amount of Water Purge

Adjustment is done by use of the control buttons

on the AutoIQ Controller. Examine the next section

to become familiar with the AutoIQ Controller

before beginning.
1. If the machine is on, push and hold the OFF

button for more than 3 seconds, then release it.

This switches the machine Off.
2. Push and hold the OFF button for more than 3

seconds (just until all lights flash on) then release

it. Do not hold it in it too long.
3. Examine the green lights. They should have all

flashed once, then certain ones will have turned on

to indicate which purge level the machine is set at.

There are 5 levels of purge available:

1. Maximum Purge is when All 5 lights are

ON. Use for extreme water conditions. Note:

This setting may extend the Harvest cycle

and reduce capacity.

2. Heavy Purge is when these 4 lights are

ON: Freeze, Harvest, Clean, Off. Use for

severe water conditions.

3. Standard Purge (factory setting) is when

these 3 lights are ON: Harvest, Clean, Off.

Use for moderate to severe water

conditions.

4. Moderate Purge is when these 2 lights

are ON: Clean, Off. This is for typical water

conditions.

5. Minimum Purge is when this light is ON:

Off. For excellent water conditions.

Adjust by pushing and releasing the Freeze button.

Pushing and releasing the Freeze button increases

the purge one level up to the maximum, then it

goes to the minimum.
4. The machine will automatically restart after 60

seconds of no switch inputs, or restart the machine

by pushing in and holding the Off button for more

than 3 seconds, then releasing it. The unit will then

be Off. From there the machine may be placed in a

freeze cycle by pushing and releasing the Freeze

button.

CME306 & CME456

January 2000

Page 20