Initial start up – Scotsman CME306 User Manual

Page 19

background image

Initial Start Up

1. Remove the front panel.
2. Locate the AutoIQ Controller.
3. Switch on the electrical power. Note that the

controller’s indicator lights all flashed on briefly,

then the two red lights flashed on and off while the

Freeze and Harvest (for CME306) or Freeze,

Harvest and Clean (for CME456) lights are on.

After 20 seconds the red lights switch off, the Bin

Full and Off lights are on and then the Bin Full light

goes out, leaving the Off light glowing.
4. Open the water supply valve.
5. Push and release the Freeze cycle push button.
Initial Start

The Freeze light will begin to blink.

The Hot Gas Solenoid valve will be open.

The Purge valve will be open.

The Water pump is on.

The hot gas and purge valves close and the

inlet water valve opens to fill the reservoir.

The inlet water valve will shut off when the

reservoir is full.

The compressor starts.

Freeze Cycle:

The Freeze indicator light will be on. The

machine will stay in a Freeze cycle for many

minutes. Slush may appear in the reservoir,

it is temporary and normal.

The fan motor (of air cooled models) will

begin to turn and soon warm air will be

forced out the back of the cabinet.

The pump will stop for a few seconds a few

minutes into the freeze cycle.

The freeze cycle will continue until the water

level in the reservoir drops to its factory set

point. At that time the CME306 proceeds to

the harvest cycle, but the CME456 will refill

the reservoir and go into harvest the NEXT

time the water level drops to the set point.

Harvest Cycle:

The Harvest indicator light will be ON,

The hot gas valve will open.

The purge valve will be open for 40 seconds.

The water pump will stop. It will restart in

less than 40 seconds.

The purge valve closes and the Inlet water

valve will open for a short time to add water.

The Bin Full indicator light will go on and off

as ice falls from the evaporators.

6. Machines are shipped from the factory with the

purge level set to accommodate average water

conditions. To achieve optimal machine

performance, set the purge level to the minimum

setting.
Note: While the amount of water purge is

adjustable, only those installations with a water

supply known to be excellent (very low ) should

adjust to the minimum setting. See page 20 for

purge adjustment instructions.
7. The machine’s correct cube size should result in

ice falling from the evaporator in vertical strips of 8

- 10 cubes.
8. After about 6 minutes the machine will return to

a freeze cycle.
Note: After the first harvest, the controller adjusts

the harvest time as needed to release all ice.

9. The water valve will re-fill the reservoir at the

beginning of freeze.
10. Collect and discard the first batch of ice. Rinse

out the bin.
11. Fill out the Customer Evaluation and Warranty

Registration. Send it to Scotsman.
12. Replace the front panel.
13. Inform the user of the location and telephone

number of the local service company. Also inform

the user of the required maintenance of the

machine.

Notes On Operation:

1. The bin control signals the ice machine to shut

off whenever the bin becomes full, but the machine

will not stop until it has finished the next harvest

cycle. This last harvest cycle will be longer than

the rest.
2. After the bin has filled the unit will not be able to

restart for 4 minutes. However, if needed, the

Freeze button may be pushed to restart the unit.
For example: If ice is removed from the bin

immediately after the machine has filled up and

shut off, the Bin Full light will be ON and the

machine will not restart for 4 minutes.
3. If the bin controls sense a bin full signal before

any water is used (float stem up), the machine will

shut off on bin full.

CME306 & CME456

March 2003

Page 19