Additional Maintenance: Air Filter Replacement

Air Filter Cleaning / Replacement - Do

Monthly

1. Remove the front panel.
2. Remove the top panel.
3. Remove the left side panel.
Remove the filter from the side panel. Wash it with

cold water to remove all embedded dust. If filter is

torn, replace it.
5. Return all panels to their original positions.

Secure them with the original screws.

Inlet Water Valve Screen - Do if water flow

becomes restricted.

The inlet water valve has a screen on its inlet side

to keep debris from flowing into the valve. In some

cases, this screen may become clogged or

restricted by debris build up. Check for the proper

water flow:
Flow rate is 1.25 G.P.M.
1. Remove front panel.
2. Obtain a measuring cup and a watch.
3. Pull the water discharge tube out of the

reservoir and place it in the cup.
4. Push and release the Harvest button.
5. If working properly, the water valve will fill an 8

oz cup in about 3-4 seconds. Be prepared to push

the Off button. If it does not, the water valve inlet

or other water device is restricted.

To Check the Inlet Water Valve Screen.

1. Disconnect the electrical power.
2. Shut off the water supply.
3. Disconnect the water supply from the ice

machine.
4. Unscrew the water fitting at the back of the ice

machine.
5. Examine the inlet screen, if dirty, brush off

screen.
Note: Screen is not replaceable, and may only be

removed by taking off the covering bracket. The

bracket forms part of the inlet water system, and

must be water tight to the valve body, removal is

not recommended.
6. Reverse to reassemble.