Electrical

All models must be installed with the correct wire

size and type per the National Electric Code.

Locate the nameplate on the back of the cabinet

and find the numbers for Voltage, Phase, Minimum

Circuit Ampacity and Maximum Fuse Size. Either

fuses or HACR type circuit breakers may be used.
Electrical connections are made in the junction box

in the back of the cabinet.
1. Remove the junction box cover.
2. Knock out 1 hole for a field supplied strain relief.
3. Install wires and strain relief per code.
4. Connect to wires and secure ground wire to

ground screw inside the junction box.

Follow all Local, State and National codes.

CME306 & CME456

January 2000

Page 14

Power IN

Electrical

Power

Supply

Power Supply Connections

Water Cooled

Connections