How To Operate The AutoIQ Controller

The AutoIQ Controller is a microprocessor based

device that receives input from several sources

and switches various components on and off.
Its manual control is thru the use of the Push

Button Control Switches

1. Freeze Button. Pushing and releasing this

button starts or restarts the machine. The

Controller remembers what cycle it was last in and

returns to that cycle.
2. Harvest Button: Pushing and releasing this

button will cause the machine to go directly to a

Harvest Cycle. Can be done from Freeze or Off.

The machine will switch Off at the end of the

Harvest cycle.
3. Clean Button: Pushing and releasing this

button will cause the machine to empty the

reservoir, refill and leave only the water pump on

for circulation of ice machine cleaner. After the ice

machine cleaner has circulated for about 10

minutes a second push of this button will switch on

the rinsing system to flush out the dissolved scale

and ice machine cleaner.
4. Off Button: Pushing and releasing this button

will switch the machine OFF at the end of the next

cycle. If the button is pushed and HELD for more

than 3 seconds, the unit will switch off

immediately.

To Reset Machine (machine off, error light on):

First push and release the Off button, then push

and release the Freeze button.
Diagnostic Light Recall
To recall the last error on the blue housing CM

3

controller:
1. Switch the unit OFF by holding the OFF button

for longer than 3 seconds.
2. Hold the Off button down again until the Purge

Setting indicators (Green Lights) are on.
3. Push and release the Harvest button.
The last error code stored in the controller will be

displayed and the purge setting will disappear.
Push the Harvest button again and the

second-to-last error code will be displayed. The bin

full light will also be on to signal that this is the

second-to-last code.
Pushing the Harvest button again will display the

last error code again. Only two error codes are

available for display.
If no error code exists, no code will be displayed

and there will be NO LIGHTS showing.
To return from the display of the last error, do

nothing for 60 seconds or push and hold the Off

button.
After returning from the display of the last error

(Off light glows), the machine may be returned to

the ice making process by pushing and releasing

the Freeze button.

CME306 & CME456

March 2003

Page 18

1

2

3

4

5

6

7

8

9

BIN FULL

FREEZE

HARVEST

CLEAN

OFF

WATER
REFRIGERATION

PUSH BUTTON

CONTROL SWITCHES

INDICATOR LIGHTS:

DIAGNOSTIC LIGHTS:

This manual is related to the following products: