Additional Maintenance

To drain reservoir completely (if desired):

1. Remove front panel.
2. Push and hold the Off button.
3. Push and hold the Clean button for 3 seconds to

activate the purge valve.

To Sanitize the Ice Storage Bin

1. Remove all ice.
2. Remove baffle.
3. Switch ice machine OFF or wait for it to be in a

cleaning cycle.
4. Mix a 1 gallon solution of warm (95-115

o

F.)

water and sanitizer. Follow local codes for

sanitizer.
5. Wash or spray the entire interior of the ice

storage bin with the sanitizer solution. This

includes the bottom of the ice machine and the

inside of the door, the door gaskets (if any) and

door frame.
6. Pour excess sanitizer into the bin to flush the

drain system.
7. If the approved sanitizer requires a rinse, rinse

all interior surfaces with potable water.

Additional Maintenance: Water Distributors

It may become necessary to remove the water

distributors from the top of the evaporator and

clean (de-mineralize) them outside of the ice

machine.
1. Remove front panel.
2. Push and release the OFF button.
3. Remove the evaporator cover.
4. Lift up at the center of the water distributors and

disconnect the distributors from the manifold.
5. Repeat for all evaporators and distributors.

6. Examine the top of the evaporators. The Water

Distribution Channels must be free from mineral

build up. If build up is evident, scrub the channels

with Scotsman Ice Machine Cleaner and a plastic

bristle brush.

7. Examine the water distributors. Although they

are made of a material that is resistant to mineral

build up, some may be present. Soak or scrub the

distributors in or with a solution of Scotsman Ice

Machine Cleaner and warm potable water.
8. Return the water distributors to their normal

installed position.

9. Return all panels to their original positions.
10. Push and release the clean button to flush the

water system.
11. After the machine stops, push and release the

Freeze button.
12. Replace the front panel.