beautypg.com

Bin thermostat: optional installation – Scotsman CME306 User Manual

Page 11

background image

CME306 & CME456

January 2000

Page 11

Bin Thermostat: Optional Installation

The normal bin control is the ice sensor set. An

option, required in some cases, is a thermostat. Its

bulb must be deployed after the ice machine has

been placed on the bin or dispenser.
Note: Some configurations may have parts that

vary from these instructions. Follow the

instructions for the particular configuration.

Before starting, remove the left side panel and any

baffle in the bin.
1. Place thermostat in machine behind the high

voltage box and secure to the existing holes with

two screws. Locate bin thermostat bulb.

2. Route bulb thru routing hole (located behind the

compressor).

3. Locate bin thermostat bracket.

4. Carefully position the thermostat bulb on the

bracket.

5. Fasten the bracket to the bottom of the ice

machine with the two 3-pronged knobs supplied

with the kit.

6. Pull excess capillary tubing into the machine..
7. Continue with the installation. If a baffle was

removed return it to its original position.
Note: If the machine is located at an altitude

higher than 2,000 ft., adjust the thermostat by

removing the plastic cover and rotating the

adjustment screw per the table.

Bin Thermostat Altitude Correction Table

CW Turns of Range Screw (under plastic cover)

Feet

Turns

Feet

Turns

2000

55

o

8000

340

o

4000

160

o

9000

385

o

Use This Table to Adjust Thermostat

Routing Hole

Bin

Thermostat

Bracket

Insert Tip

Thermostat

Body