Technicians Only: Freeze Cycle Operational Sequence

Assuming the machine has been operational, the

Freeze cycle begins with the end of Harvest:

Condenser fan is OFF

Water Inlet Valve is CLOSED

Water Pump may be ON

Compressor is ON

Hot Gas Valve is OPEN

The Controller, from the start of the freeze

cycle:

1. Switches on the Freeze indicator light and shuts

off the hot gas valve.
2. Opens the water valve to top off the reservoir.

Water must fill the reservoir within 130 seconds or

the controller shuts the machine down. It will

automatically try to restart in 20 minutes.
3. Measures the discharge temperature.
4. Starts the fan motor (air cooled only). The

Controller checks the discharge temperature and

cycles the fan(s) on every 12 seconds and off for

20 seconds (CME456) or 45 seconds (CME306) if

the temperature is low.
If the discharge temperature exceeds the design

maximum the controller shuts the unit off.
5. Checks for a “bin full" signal throughout the

cycle.
6. Measures the reservoir water temperature. If the

machine is operating correctly, the reservoir water

temperature will fall at a standard rate. The

Controller will be checking to see if the water

temperature fall matches that rate.
If not, it re-checks the discharge line temperature.

If too low, it stops the unit. If the discharge

temperature is acceptable, the water system is

checked by shutting off the water pump and

determining if the water level goes up enough. If it

does not, it is assumed that there is a water pump

problem and the controller shuts the unit off.
If the water level does “measure up" the water

pump is restarted and the AutoIQ Controller then

measures how long it takes to lower the water

level. If the water level does not fall, the machine

Shuts Down on a Water Error.
7. Once per cycle the machine will shut off the

water pump. It only does this when the water

temperature reaches a preset minimum. The pump

will only be off for a few seconds. After the pump

restarts, the inlet water valve opens to refill the

reservoir.
8. As the machine makes ice, the water level in the

reservoir will ultimately fall to the Harvest Level .

CME306 fills the reservoir once at the

beginning of Freeze

CME456 fills the reservoir at the beginning

of freeze and one more time about ½ way

through freeze.

Air cooled models will switch off the fan motor a

few seconds before harvest begins.
Note: If the freeze cycle exceeds the preset

Maximum (45 minutes), the Controller will shut the

unit off.

9. At the end of Freeze cycle:

Water level = below harvest position

Condenser fan will be off

Water inlet valve will be off

Water pump will be ON

Compressor will be ON

Hot gas valve will be off

At this point Harvest begins and the AutoIQ

Controller switches the Harvest indicator light ON.
Restarts:
If restarting after shutting off because the bin was

full, the first freeze cycle sequence is like this:
1. Purge valve is open.
2. Pump starts.
3. Purge valve closes.
4. Water valve opens to fill the reservoir.
5. Compressor starts.
Note: If there is a power interruption, after power is

restored the machine will restart, go thru a brief

Freeze cycle and then go thru a 5 minute Harvest

cycle. The Freeze light will be blinking - even when

the machine is in harvest.

Error Restarts:
The machine automatically attempts to restart 50

minutes after a shut down. If another problem

occurs in the next cycle, the machine will attempt

one more restart. If another problem occurs in the

next cycle, the machine will be off and must be

manually reset.