Rena T-650 User Manual
Page 55

OPERATION
8. The Tab Sensor 2 Setup screen will
appear.
Select Automatic.
9. The Select Tab Type Before
Calibration screen will appear.
Select the Tab Type, either Opaque or
Clear, based on the table below.
For the purpose of this example we
will select Opaque.
TAB TYPE
SELECT
Stock that has a white space (gap)
between each tab/stamp.
Opaque
Stock that has a black space (gap)
between each tab.
Clear
” for additional help.
10. Once the Tab Type is selected, the
tabber transport will start and the
screen at the right will appear.
Adjust the speed control dial on the
tabber either up or down until the
“Feed 1 Product now” appears in the
display.
11. Set the feeder’s speed control to zero.
Turn the feeder on.
Using the Feeder’s jog button, feed one
piece of media into the tabber.
Two or three tabs will be applied to the
piece and then the tabber will stop and
display the new V-Tab values. The Tab
sensor is now setup for this tab stock.
Tip: In order for the tabber to distinguish between the Tab and Backing, the voltage
difference between the Gap V and Tab V must be 0.80 volts or greater. If the difference
is lower, check/clean the sensor and then repeat the V-Tab adjustment. If the value is still
less than 0.80 volts difference then you may need to use another tab stock that has a
larger density difference. To check the function of the tab sensor, see “
T-650 Operations REV. 8/25/2010
55