beautypg.com

View alarms, Display all alarms, Display active alarms – Quintum Technologies Tenor DX User Manual

Page 87: View alarms -7, Display all alarms -7, Display active alarms -7

background image

P/N 480-0049-00-10

8-7

Chapter 8: System Alarms

View Alarms

The Command Line Interface (CLI) enables you to view alarms through the Monitor mode. You can view
active alarms, as well as view an alarm history list.

You are now ready to view active alarms and an alarm history, or both. See the sections which follow:

Display all Alarms

You are able to display both active alarms and an alarm history as follows:

1. Through CLI, access the Monitor prompt.

2. Type alarm. Both active alarms and the alarm history will be displayed. See section How to Read Alarms

for field definitions.

Figure 8-1 Alarm sample

Display Active Alarms

1. Through CLI, access the Monitor prompt.

2. Type alarm a. The active alarms will be listed. See section How to Read Alarms for field definitions. If

you enter alarm without a command following it, both active alarms and the alarm history will be dis-
played.

Figure 8-2 Active Alarm Sample

IP# Sequence#Type#Severity# Desc# Slot# Device# Digital Interface# Channel# Date/Time

192.168.20.136:947:ALR:1:Yellow Alarm:1:0:1:0:THU APR 14 00:00:04 2016

IP# Sequence#Type#Severity# Desc# Slot# Device#Digital Interface# Channel# Date/Time

192.168.20.136:947:ALR:1:Yellow Alarm:1:0:1:0:THU APR 14 00:00:04 2016