beautypg.com

Quintum Technologies Tenor DX User Manual

Page 83

background image

P/N 480-0049-00-10

8-3

Chapter 8: System Alarms

Severity

Level or alarm severity.

1 = Critical (complete system is
affected).
2 = Major (major problem is
detected).
3 = Minor (minor problem is
detected).
4 = Info (Information about a
minor problem).

Description

A text description of the alarm;
see Table 8-2 for detailed descrip-
tion.

Varies.

Slot #

Defines which slot the alarm
occurred on.

Slot 1 or 2. Slot 1 refers to the
system controller functions; slot
2 refers to DSP functions.

Device #

Defines which device the alarm
occurred on.

Always device 0.

Digital Interface

Defines which interface (line) the
alarm occurred on.

Line 1 through 8.

Channel #

Specifies which channel the alarm
occurred on.

Channels 1-24 (for T1) or 1-31
(for E1).

Date/Time

Date/time the event occurred on.

Day of week: name of day.
Month: Jan, Feb, March, etc.
Day of month: 1 or 2 digits.
Time: 6 digits (hour minutes sec-
onds based on a 24-hour clock).
Year: 4 digits.

Field

Definition

Valid Entry