Chapter 3: Installation

Rack Install

Locate the Tenor DX unit within the same area as your PBX, Ethernet hub, switch, router, and/or PSTN patch
panel. The chassis is intended to be installed in a 19” rack.

Mounting brackets are attached to the chassis; the rack is not included with your system. Included with the
chassis are the screws and clip nuts listed below. The sizes should allow installation in most racks. If your rack
does not use the same size screws listed in the table, please consult the instructions you received with the rack.

Required Materials

19” rack (not included with system)

#8 - 32 x 3/8 screws (qty: 2) (included with system)

screws as required by your rack manufacturer

Install the chassis in a rack as follows:

1. Choose a position for the chassis within the rack.

WARNING:

If the Tenor DX unit is the only equipment installed in the rack, ensure it is level with the rack
to avoid the rack from becoming unbalanced. Mount as low as possible to avoid a high center
of gravity.

2. Align the unit’s mounting brackets flush with the rack’s mounting holes (see Figure 3-1) and follow the

vendor specific instructions for rack installation. The screws provided require a Phillips #2 screwdriver.

3. Ensure the chassis is secured firmly to the rack.