beautypg.com

Measurement Computing DaqBook 2000 Series User Manual

Page 55

background image

4. Test the system connections.

a. Make sure the device has been properly installed and is powered-on.
b. Make sure all cables are properly and securely connected.
c. Click the “Test Hardware” tab.
d. Click the <TCP/IP Test> button. This tests the Transmission Control Protocol / Internet

Protocol. The TCP/IP test has two components: Pinging Device and TCP Connection.

The Pinging Device test is an ICMP (Internet Control Message Protocol) ping test. In

addition to indicating either “Passed” or “Failed,” the test displays the round-trip time of the

ping, for example, <10 ms; and Packet Loss expressed as a percent of data lost.

A long ping round trip time, for example, >50 ms and/or any packet loss indicates a slow

network that is not optimized.

If the Pinging Device Test fails a <Details> button will appear just above the <Resource

Test> button. If this is the case, click the <Details> button to obtain possible causes and

possible solutions.

The result of the TCP (Transmission Control Protocol) test will be either passed or failed.

If the TCP test failed a <Details> button will appear just above the <Resource Test> button.

If this is the case, click the <Details> button to obtain possible causes and possible solutions.

e. Upon completion of the TCP/IP test, click the <Resource Test> button. The Resource Test

consists of two components: Resource Tests and Performance Tests.

The Resource Test performs a quick communications check. If the host PC can

communicate with the device a message that the test passed is displayed.

The Performance Tests obtain quantitative results using the current configuration of the

acquisition device. The test results represent the maximum rates at which various operations

can be performed, and will vary according to port hardware capabilities.
The ADC FIFO Input Speed part of the test results in a display of the maximum rate at which

data can be transferred from the tested device’s internal ADC FIFO to computer memory.

Results are given in samples/second, where a sample (2 bytes in length) represents a single

A/D value.

When testing a DaqBook/2000 or a DaqOEM/2000 Series device, if the unit does not

respond within 30 seconds perform the following steps:

1) reboot the system
2) upon power-up, re-open the Daq* Configuration
applet
3) select another configuration setting
4) reinitiate the test

This completes the procedure for connecting a DaqBook/2020, DaqBook/2001, DaqBook/2005,

DaqOEM/2001, or DaqOEM/2005 to the Ethernet.

DaqBook/2000 and DaqOEM/2000 Series

898095

Configuring the System for Operation 6-13

This manual is related to the following products: