beautypg.com

31 @aace – Measurement Computing CB-7011 User Manual

Page 53

background image

53

CB-7011/CB-7011D, CB-7018 User’s Manual

2.31 @AACE

Description: Clear Event Counter

Note: The command is for CB-7011/11D/11P/11PD only.

Syntax: @AACE[CHK](cr)

@

delimiter character

AA

address of setting module (00 to FF)

CE

command for clear event counter

Response: Valid Command:

!AA[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax error or communication error may get no re-

sponse.

!

delimiter for valid command

?

delimiter for invalid command

AA

address of response module(00 to FF)

Example:

Command: @01RE

Receive: !0101234

Read address 01 event counter, return 1234.

Command: @01CE

Receive: !01

Clear address 01 event counter, return success.

Command: @01RE

Receive: !0100000

Read address 01 event counter, return 0.

Related Command:

Sec. 2.30 @AARE

Related Topic:

Sec. 3.4 Digital Input and Event Counter