CB-7011/CB-7011D, CD-7018 User’s Manual
2.13 $AA8V
Description: Set LED Configuration
Note: The command is for CB-7011D/11PD only.
Syntax: $AA8V[CHK](cr)
$
delimiter character
AA
address of setting module (00 to FF)
8
command for setting LED configuration
V
1=Set LED to module, 2=Set LED to host
Response:
Valid Command:
!AA[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax error or communication error may get no
response.
!
delimiter for valid command
?
delimiter for invalid command
AA
address of response module(00 to FF)
Example:
Command: $0182
Receive: !01
Set address 01 LED to host control, return success.
Command: $0281
Receive: !02
Set address 02 LED to module control, return success.
Related Command: