16 $aaf – Measurement Computing CB-7011 User Manual
Page 37
37
CB-7011/CB-7011D, CB-7018 User’s Manual
2.16 $AAF
Description: Read Firmware Version
Syntax: $AAF[CHK](cr)
$
delimiter character
AA
address of reading module (00 to FF)
F
command for reading firmware version
Response: Valid Command:
!AA(Data)[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
!
delimiter for valid command
?
delimiter for invalid command
AA
address of response module(00 to FF)
(Data)
firmware version of module
Example:
Command: $01F
Receive: !01A2.0
Read address 01 firmware version, return version A2.0.
Command: $02F
Receive: !01B1.1
Read address 02 firmware version, return version B1.1.