22 @aado(data) – Measurement Computing CB-7011 User Manual
Page 44
44
CB-7011/CB-7011D, CD-7018 User’s Manual
2.22 @AADO(Data)
Description: Set Digital Output
Note: The command is for CB-7011/11D/11P/11PD only.
Syntax: @AADI[CHK](cr)
@
delimiter character
AA
address of setting module (00 to FF)
DO
command for setting digital output
(Data)
output value, 00=DO0 off, DO1 off, 01=DO0 on, DO1
off, 02=DO0 off, DO1 on, 03=DO0 on, DO1 on
Response: Valid Command:
!AA[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
!
delimiter for valid command
?
delimiter for invalid command. When the alarm is
enabled, the command will return invalid.
AA
address of response module(00 to FF)
Example:
Command: @01DO00
Receive: !01
Set address 01 digital output 00, return success.
Related Command:
@AADI (Sec. 2.21), @AAEAT (Set. 2.23), @AADA (Sec. 2.26)
Related Topic:
Sec. 3.5 Digital Output