beautypg.com

Mounting the machine torch – Hypertherm HT2000-200 Volt User Manual

Page 87

background image

INSTALLATION

4-34

HySpeed HT2000

Instruction Manual

19

Torch Alignment

Prior to cutting with the machine torch, ensure that the torch is at right angles to the workpiece to get a clean,
vertical cut. Use a square to align the torch. The torch should be aligned at 0° and 90° (Figure 4-20).

Figure 4-20

Torch Alignment

(shown without IHS probes)

Figure 4-19

Mounting the Machine Torch

(shown with IHS probes)

Torch leads

Torch sleeve

Securing
screw

Torch mounting
bracket with IHS

Workpiece

Securing screws

Torch sleeve

Torch mounting
bracket without IHS

Mounting the Machine Torch

1. Loosen

Securing screw(s)

and install the machine torch (with torch leads attached) in the torch mounting

bracket or the torch mounting subassembly if IHS is used. See Figure 4-19 for torch mounting bracket with

IHS, and Figure 4-20 for torch mounting bracket without IHS.

2. Position the torch until the torch body extends all the way through the bracket, so that the bracket is now

around the plastic

Torch sleeve

and not touching the stainless steel torch body. Position the torch

approximately .25 " (6mm) from the work surface.

3. Tighten the securing screw(s). Final adjustment of the torch height is detailed in

Section 5: Post-

Installation

.

Argon-Hydrogen Connections

See

Section 7

: Operation: Argon-Hydrogen Manifold.