PRE-INSTALLATION
HySpeed HT2000
Instruction Manual
3-3
19
WARNING
Cutting with oxygen as the plasma gas can cause a potential fire hazard due to the oxygen-
enriched atmosphere that it creates. As a precaution, Hypertherm recommends that an exhaust
ventilation system be installed if you will be cutting with oxygen.
Oxygen, Nitrogen, or Argon-Hydrogen as Plasma Gas
From Source Supply to Gas Console
Refer to
Section 2
for gas specifications.
If
not
using hard plumbing to supply plasma gas to the gas console, we recommend using standard oxygen
hose with the system.
Note: If cutting with oxygen as the plasma gas, nitrogen must also be connected to the gas
console to achieve the proper oxygen/nitrogen mixtures in the preflow and cut flow
conditions.
From Gas Console to Motor Valve Console
Hose from the gas console to the motor valve console is provided by Hypertherm.
Shield Gas
From Source Supply to Gas Console
Refer to
Section 2
for gas specifications.
If
not
using hard plumbing, use 3/8-inch I.D. hose with the system. Hose can also be purchased through
Hypertherm.
From Gas Console to RHF Console
Hosing from the gas console to the RHF console is provided by Hypertherm.