Aluminum, Above water only, 40 amps • air plasma / air shield – Hypertherm HT2000-200 Volt User Manual
Page 129
6-34
HySpeed HT2000
Instruction Manual
OPERATION
22
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (Air)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(Air %)
(Air %)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
3/32
2.5
40
20
60
3/32
2.5
3/16
5
120
140
3550
1/8
3
(46.0
(23.1
(275
3/32
2.5
3/16
5
130
100
2550
0.5
1/4
6
SCFH)
SCFH)
SCFH)
1/8
3
140
35
900
3/8
10
1/8
3
150
15
350
Aluminum
40 amps • Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical.
Notes:
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
Production cutting above 1/8" (3 mm) not recommended
Above Water Only
020613
Swirl ring
120667
Electrode
020689
Nozzle
020423
Retaining cap
020688
Shield