MAINTENANCE

HySpeed HT2000

Instruction Manual

8-17

19

Problem

Possible Causes

/ Solutions

5. PLASMA GAS LED

illuminated:

5.1. Plasma gas pressure too low.

This LED will extinguish when PS1 and/or PS2 in the gas

console senses plasma gas pressure of 80 psi (5.5 bar) or

greater.

• Verify that plasma gas supply is set to 120 psi (8.3 bar) as

defined in

Section 2

of this manual.

• Verify that all plasma gas connections are secure, and

that there are no leaks in any hoses connected to the gas

console.

5.2. Pressure switches PS1 and/or PS2 not functioning.

These switches are normally open, and close when plasma

gas pressure is at or above 80 psi (5.5 bar). After PS1 and

PS2 are closed (in O

2

mode) or PS1 is closed (in N

2

mode),

the

PLASMA GAS

LED extinguishes.

• Using the wiring diagrams, check pins, connectors and

associated wiring from the power distribution board

(PCB1) to PS1 and PS2.

Repair and/or replace defective component(s), if necessary.

6. COOLANT TEMP LED

illuminated:

6.1. Coolant too hot

.

This LED will extinguish when temperature switch TS2

senses that the temperature of coolant in the coolant

reservoir is under 160°F (71°C).

• Check to see if water coolant is above 160°F.

• Check to see if TS2 (located in the coolant reservoir) is

open. TS2 is normally closed, and is opened when a

temperature above 160°F (71°C) is reached.

• Using wiring diagrams, check pins, connectors and

associated wiring from REC3 on the power distribution

board (PCB1) to PS3.

Repair and/or replace defective component(s), if necessary.