Hypertherm HT2000-200 Volt User Manual
Page 142

OPERATION: ARGON-HYDROGEN MANIFOLD
HySpeed HT2000
Instruction Manual
7-5
19
Plasma gas torch lead – Argon-Hydrogen Manifold to Torch (Fig. 7-5)
A. Turn all plasma and shield gas supply tanks
OFF
.
B. Remove the existing
Plasma gas torch lead
from
Point 1
.
C. Attach one end of the argon-hydrogen plasma gas torch lead (Fig. 7-4) to the
Plasma gas torch lead
connection
located on the front of the manifold. (Fig. 7-5)
D. Attach the other end of the plasma gas torch lead to
Point 1
on the torch
.
(Fig. 7-5)
Figure 7-5
Argon-Hydrogen Manifold to Torch Connection Points
Figure 7-6
Nitrogen Supply to Gas Console
Nitrogen supply to Gas Console (Fig. 7-6)
Connect the nitrogen supply to the shield connection at the rear of the gas console. (Fig. 7-5)
2WRENCHES
Ni
trogen
Plasma gas
torch lead
Point 1
Torch
Plasma gas
torch lead
connection