INSTALLATION
4-32
HySpeed HT2000
Instruction Manual
19
Optional Power Supply Connections
Timer/Counter to Power Supply
Timer/Counter cable – Power Supply to Timer/Counter
Hold Cable Connections (When using Multi-Torch Systems)
If a multi-torch system is being used (more than one power supply), make the following connections at both
power supplies:
Hold Cable Connections – Power Supply 1 to Power Supply 2
Legend – To HT2000 TB3 – Both Ends
Wire Color
To HT2000
Function
TB3
–
Black
13
Hold Signal
–
Red
14
Hold Common
GND
Shield
15
Hold Shield
26
27
11X1
Black
Black
Red
Red
GND
GND
From Timer/Counter To HT2000
Color
Function
11X1
TB3
1
2
White
Starts & Arc time (CON1 Closed)
2
1
Black
Starts & Arc time (CON1 Closed)
3
3
Drain
Drain
15
5
Red
Error Counter (Ramp Down Error)
16
4
Black
Error Counter (Ramp Down Error)
12
6
Drain
Drain
Part No.
Length
Part No.
Length
023687
10 ft (3 m)
023692
25 ft (7.6 m)
023758
38 ft (12 m)
023693
50 ft (15 m)
023694
75 ft (23 m)
023695
100 ft (30 m)
023696
150 ft (46 m)
Part No.
Length
023340
15 ft (4.5 m)
023341
25 ft (7.6 m)
023342
50 ft (15 m)
023343
100 ft (30 m)
023344
150 ft (46 m)