Stainless steel, Above water only, 40 amps • air plasma / air shield – Hypertherm HT2000-200 Volt User Manual
Page 122

HySpeed HT2000
Instruction Manual
6-27
OPERATION
22
Shield
Arc
Approx.
Material
Plasma Gas Flow Rate %
Gas (Air)
Torch-to-work
Initial Torch
Voltage
Motion
Thickness
Preflow
Cutflow
Pressure
Distance
Piercing Height
Setting
Travel Speed
Delay Time
(inches)
(mm)
(Air %)
(Air %)
(psi)
(inches)
(mm)
(inches)
(mm)
(volts)
(ipm) (mm/min.)
(sec)
.050
(18 GA.)
40
20
60
3/32
2.5
3/16
5
120
145
3700
1/16
1.5
(46.0
(23.1
(275
3/32
2.5
3/16
5
120
120
3050
1/8
3
SCFH)
SCFH)
SCFH)
3/32
2.5
3/16
5
125
75
1900
0.5
1/4
6
1/8
3
135
24
610
3/8
10
1/8
3
140
12
300
Stainless Steel
40 amps • Air Plasma / Air Shield
This gas combination gives good cut speed, low dross level and is very economical. Some surface nitriding and
surface oxidation of alloying elements can occur.
Notes:
Set air plasma gas inlet pressure to 90 psi (6.2 bar)
Set air shield gas inlet pressure to 90 psi (6.2 bar)
Production cutting above 1/8" (3 mm) not recommended
Above Water Only
020688
Shield
020423
Retaining cap
020689
Nozzle
020613
Swirl ring
120667