Coolant flow test procedure – Hypertherm HT2000-200 Volt User Manual
Page 170
![background image](https://www.manualsdir.com/files/789752/content/doc170.png)
MAINTENANCE
HySpeed HT2000
Instruction Manual
8-25
20
Coolant Flow Test Procedure
If the COOLANT FLOW Status LED illuminates, verify that the proper flow is maintained by following the
troubleshooting sequence outlined in this procedure:
Check Reservoir Coolant
1. Shut off power supply (see warning above).
2. Remove the torch coolant reservoir cap.
3. Remove the power supply rear cover.
4. Verify that the reservoir is full of coolant. Add coolant, if necessary.
Verify Flow Rate Return from Torch
1. Find a clean one-gallon container.
2. Locate the two coolant hoses that come off of the cathode block at the rear of the power supply (black
hoses: one with a green tape band and one with a red tape band - See Fig. 8-6).
3. Remove the torch coolant return hose (black hose with the red band) from the cathode block.
WARNING
Push OFF (0) button on power supply and turn main disconnect switch OFF before proceeding.
Torch Coolant Supply Hose
(Black with Green Band)
Cathode Block
Torch Coolant Return Hose
(Black with Red Band)
Remove this hose
Figure 8-6
Torch Coolant Supply and Return Hoses