After cutting with argon-hydrogen – Hypertherm HT2000-200 Volt User Manual
Page 145
OPERATION: ARGON-HYDROGEN MANIFOLD
7-8
HySpeed HT2000
Instruction Manual
20
After Cutting with Argon-Hydrogen
1. Turn MV1 to the closed position.
2. Disconnect the 14X1 argon-hydrogen cable at the cable connection
point of the argon-hydrogen manifold. See Figure 7-2.
3. Remove the argon-hydrogen plasma gas torch lead from point 1 of
the torch. See Figure 7-5.
4. Connect the machine torch plasma hose from the motor valve console
to point 1 of the torch. See
Connecting the Off-Valve Cable and
Plasma Hose from the Torch to the Motor Valve Console
in Section 4.
5. Remove the nitrogen supply hose from the shield supply connection
of the gas console.
6. Connect the nitrogen supply hose to the N
2
connection of the gas
console. See Figure 7-7.
7. Connect the shield gas supply hose to the shield supply connection of
the gas console. See
Gas Console Connections
in Section 4.
2WRENCHES
Ni
trogen
Figure 7-7 Nitrogen Supply to N
2
Input of Gas Console
MV1
FM1