Rhf and motor valve consoles to torch connections, Routing the torch leads, Connecting the hf torch leads to the rhf console – Hypertherm HT2000-200 Volt User Manual
Page 81

INSTALLATION
4-28
HySpeed HT2000
Instruction Manual
19
RHF and Motor Valve Consoles to Torch Connections
See pages 4-6 through 4-9 for RHF connections to power supply, and page 4-12 for motor valve console
connection to power supply. See also page 4-26 for RHF and motor valve console connections to gas
console.
Routing the Torch Leads
Prior to connecting the torch leads to the RHF console, motor valve console and torch, the torch leads must
be routed between the cutting machine, RHF console, motor valve console and the torch. See Figure 4-2 for
an example. You will generally need to route the leads through a festoon or a power track.
Caution:
Before routing the leads, make sure the torch is removed from the torch leads.
Damage to the torch could result from dropping, banging, or scraping. Once the
torch leads have been routed, proceed with torch connections.
Connecting the HF Torch Leads to the RHF Console
Torch Leads – HF Torch Leads to RHF Console – Fig. 4-16
A. Route the HF torch leads through the
Torch Brass Fitting
on the RHF console and connect the
Torch
Coolant Hose (w/Red Band)
to the red fitting on the brass cathode block located in the RHF console.
Tighten using a 1/2" open-end wrench.
B. Connect the
Torch Coolant Hose (w/ Green Band)
to the green fitting on the brass cathode block.
Tighten using a 1/2" open-end wrench.
C. Connect the
Cap-On Sensor Hose (Gray)
to the adapter in the console.
D. Connect the
Pilot/Shield Gas Hose (Blue)
to the bulkhead adapter.
24
Torch End
Pilot/Shield Gas (Blue)
Gray
Red
Green
Red
Green
Gray
Pilot/Shield Gas (Blue)
HF Console End
Part No.
Length
Part No.
Length
028657
10 ft (3 m)
028658
15 ft (4.5 m)
028659
20 ft (6 m)
028546
25 ft (7.5 m)
028660
30 ft (9 m)
028661
35 ft (10.6 m)
028662
40 ft (12 m)
028663
45 ft (13.7 m)
028547
50 ft (15 m)