Hypertherm HT2000-200 Volt User Manual
Page 41
SPECIFICATIONS
2-10
HySpeed HT2000
Instruction Manual
19
Initial Height Sensing (#028390) – Optional
Input Power................................................................120 VAC from power supply
Air Pressure ..............................................................20 psi (1.4 bar) regulated shop air input
to solenoid.
Dimensions and Weight:
Width..........................................................................9" (23 cm)
Height ........................................................................4.5" (11 cm)
Depth ........................................................................11-1/2" (29 cm)
Weight........................................................................13 pounds (6 kg)
Figure 2-6
Mounting Dimensions – IHS Console
Timer/Counter (#073194) - Optional
Dimensions and Weight:
Width..........................................................................6-1/2" (16.5 cm)
Height ........................................................................2-1/2" (6.4 cm)
Depth ........................................................................8-5/8" (21.9 cm)
Weight........................................................................3 pounds (1 kg)
Water Muffler – Optional
The water muffler can not be used with the stainless steel machine torch
.
Refer to Water Muffler Instruction Manual (#802050).
6"
10.75"
11.5"
8"
5/16"
dia. (4)