SPECIFICATIONS

2-6

HySpeed HSD130 RHF

Instruction Manual

Noise levels

Measurements were made in a Hypertherm engineering laboratory, with other equipment operating nearby, in
accordance with Hypertherm instruction ESI-034. These measurements only provide a general indication of the noise
produced by the plasma system. Sound measurements should be taken after installation to determine the specific
noise levels at the site. Measurements were taken at distances of 1 m, 2 m, 3 m, and 5 m (straight-line distance)
from the center of the arc. An operator standing at the CNC controller would be approximately 1 m from the arc. All
measurements were made with a Bruel & Kjaer sound meter mounted on a tripod at a height of 336.55 mm (13.25 inch)
above the center of the arc.

Distance from the center

of the arc

Ambient room noise

Process 1

H35/N

2

130 Amps

Process 2

Air/Air 130 Amps

1 m (3.3 ft)

80-84 dB

104-106 dB

106-108 dB

2 m (6.6 ft)

80-84 dB

97-99 dB

99-100 dB

3 m (9.9 ft)

80-84 dB

94-96 dB

96-97 dB

5 m (16.5 ft)

80-84 dB

93-97 dB

94-96 dB