Aluminum, Air plasma / air shield 45 a cutting, Metric – Hypertherm HSD130 HySpeed Plasma User Manual
Page 134: English

OPERATION
4-20
HySpeed HSD130 RHF
Instruction Manual
Aluminum
Air Plasma / Air Shield
45 A Cutting
220532
220525
220529
220528
Metric
Plasma
Shield
Plasma
Shield
mm
Volts
mm
factor %
seconds
0.5
113
3.0
200
0.0
0.8
116
3.0
200
0.1
1.0
117
3.6
200
0.1
1.2
118
3.6
200
0.2
1.5
119
3.6
200
0.2
2.0
120
4.0
200
0.2
2.5
120
4.0
200
0.3
3.0
121
4.0
200
0.3
4.0
122
4.6
200
0.4
6.0
130
5.0
200
0.5
English
Plasma
Shield
Plasma
Shield
in
Volts
in
factor %
seconds
0.016
113
0.120
200
0.0
0.020
114
0.120
200
0.0
0.025
115
0.120
200
0.0
0.032
116
0.120
200
0.1
0.040
117
0.140
200
0.1
0.051
118
0.140
200
0.2
0.064
119
0.140
200
0.2
0.081
120
0.160
200
0.2
0.102
120
0.160
200
0.3
1/8
121
0.160
200
0.3
3/16
122
0.180
200
0.4
1/4
130
0.200
200
0.5
62
73
62
73
.090
.100
40
65
.060
.060
.060
.060
.070
.070
.070
.080
.080
150
110
90
.080
270
250
220
185
1950
1150
310
300
5000
3950
2950
2400
7600
6900
6350
5800
2.0
2.0
2.3
2.5
Set
Cutflow
Select
Gases
Torch-to-Work
Distance
Cutting Speed
1.5
1.5
1.8
1.8
1.8
2.0
Pierce Delay
Time
mm
mm/m
Air
Air
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting Speed
Initial Pierce Height
Pierce Delay
Time
in
ipm
Select
Gases
Set
Cutflow
Material
Thickness
Arc
Voltage
Initial Pierce Height
Air
Air
290
Flow Rates – lpm/scfh
Air
Preflow
149 / 315
Cutflow
161 / 342
220578
220490 (no IHS tab)