Daily start-up -3, Check torch -3, Daily start-up – Hypertherm HSD130 HySpeed Plasma User Manual
Page 117
Daily start-up
Prior to start-up, ensure that your cutting environment and that your clothing meet the safety requirements outlined in the
Safety section of this manual.
Check the torch
1. Turn OFF the main disconnect switch to the power supply.
2. Remove the consumables from the torch and check for worn or damaged parts. Always place the consumables
on a clean, dry, oil-free surface after removing. Dirty consumables can cause the torch to malfunction.
• Refer to Changing consumable parts later in this section for details and for consumable inspection tables.
• Refer to Consumable selection to choose the correct consumables for your cutting needs.
3. Replace consumables. Refer to Changing consumable parts later in this section for details.
4. Ensure that the torch is perpendicular to the workpiece.
Torch
Current ring
Electrode
Swirl ring
Nozzle
OPERATION
HySpeed HSD130 RHF
Instruction Manual
4-3
Shield
Retaining cap
WARNING
Before operating this system, you must read the Safety section thoroughly! Turn OFF the power
supply’s main disconnect switch before proceeding with the following steps.